{"id":15563,"date":"2019-01-14T12:44:39","date_gmt":"2019-01-14T12:44:39","guid":{"rendered":"https:\/\/www.spcsupportinfo.com\/SPCConnectPro\/?page_id=15563"},"modified":"2019-01-14T12:44:39","modified_gmt":"2019-01-14T12:44:39","slug":"all-okay","status":"publish","type":"page","link":"https:\/\/www.spcsupportinfo.com\/SPCConnectPro\/?page_id=15563","title":{"rendered":"Staff protection \u2013 Duress alternative"},"content":{"rendered":"<div id=\"pl-15563\"  class=\"panel-layout\" ><div id=\"pg-15563-0\"  class=\"panel-grid panel-has-style\" ><div class=\"siteorigin-panels-stretch panel-row-style panel-row-style-for-15563-0\" data-stretch-type=\"full-stretched-padded\" ><div id=\"pgc-15563-0-0\"  class=\"panel-grid-cell\" ><div id=\"panel-15563-0-0-0\" class=\"so-panel widget widget_sow-editor panel-first-child panel-last-child\" data-index=\"0\" ><div class=\"so-widget-sow-editor so-widget-sow-editor-base\">\n<div class=\"siteorigin-widget-tinymce textwidget\">\n\t<p>It is key to protect staff at all times and when a member of your staff has access to secure premises that may contain valuables there is a threat, traditionally the method for signally this was a member of staff to trigger a silent alarm that would be reported to police or to enter a special code often referred to as a duress code. (<a href=\"https:\/\/www.spcsupportinfo.com\/SPCConnectPro\/?page_id=11382\">These code option and the silent panic\/hold up are available on the SPC syste<\/a>m). The issue that we sometimes hear is that for duress add one to a four-digit number is hard when you are under pressure.<\/p>\n<p>The SPC Intrusion system has a number of features that help protect staff but one of the key features for this area is the \u201cAll okay\u201d function, every simply this is a step that the user performs to signal everything is Okay when they unset the system, and the nice thing about this is that the SPC will allow this step to be almost anything, and also you\u00a0 can multiple elements that can trigger the signal.<\/p>\n<p>The SPC system can be configured to have this functionality for certain areas and the time and action can be defined for what will happen if the signal is not given. The user can use any input\/zone\/ <a href=\"https:\/\/www.spcsupportinfo.com\/SPCConnectPro\/?page_id=13863\">indication module<\/a> (<a href=\"https:\/\/www.spcsupportinfo.com\/SPCConnectPro\/?page_id=13863\">SPCE110<\/a>)\/ <a href=\"https:\/\/www.spcsupportinfo.com\/SPCConnectPro\/?page_id=13863\">key switch module<\/a> (<a href=\"https:\/\/www.spcsupportinfo.com\/SPCConnectPro\/?page_id=13863\">SPCE120<\/a>) .<\/p>\n<p>&nbsp;<\/p>\n<p>The core element here is that it is easy for staff to remember not to perform an action and also more natural. The \u201cAll Okay\u201d functionality we hope you will consider this option when designing your next system as we work to improve operations and protect staff.<\/p>\n<\/div>\n<\/div><\/div><\/div><div id=\"pgc-15563-0-1\"  class=\"panel-grid-cell\" ><div id=\"panel-15563-0-1-0\" class=\"so-panel widget widget_sow-image panel-first-child panel-last-child\" data-index=\"1\" ><div class=\"so-widget-sow-image so-widget-sow-image-default-d6014b76747a-15563\">\n\n<div class=\"sow-image-container\">\n\t\t<img src=\"https:\/\/www.spcsupportinfo.com\/SPCConnectPro\/wp-content\/uploads\/2018\/10\/ACT-Enterprise-app-user.jpg\" width=\"5616\" height=\"3744\" srcset=\"https:\/\/www.spcsupportinfo.com\/SPCConnectPro\/wp-content\/uploads\/2018\/10\/ACT-Enterprise-app-user.jpg 5616w, https:\/\/www.spcsupportinfo.com\/SPCConnectPro\/wp-content\/uploads\/2018\/10\/ACT-Enterprise-app-user-300x200.jpg 300w, https:\/\/www.spcsupportinfo.com\/SPCConnectPro\/wp-content\/uploads\/2018\/10\/ACT-Enterprise-app-user-768x512.jpg 768w, https:\/\/www.spcsupportinfo.com\/SPCConnectPro\/wp-content\/uploads\/2018\/10\/ACT-Enterprise-app-user-1024x683.jpg 1024w, https:\/\/www.spcsupportinfo.com\/SPCConnectPro\/wp-content\/uploads\/2018\/10\/ACT-Enterprise-app-user-600x400.jpg 600w, https:\/\/www.spcsupportinfo.com\/SPCConnectPro\/wp-content\/uploads\/2018\/10\/ACT-Enterprise-app-user-272x182.jpg 272w\" sizes=\"(max-width: 5616px) 100vw, 5616px\" alt=\"\" loading=\"lazy\" \t\tclass=\"so-widget-image\"\/>\n\t<\/div>\n\n<\/div><\/div><\/div><\/div><\/div><div id=\"pg-15563-1\"  class=\"panel-grid panel-has-style\" ><div class=\"siteorigin-panels-stretch panel-row-style panel-row-style-for-15563-1\" data-stretch-type=\"full-stretched-padded\" ><div id=\"pgc-15563-1-0\"  class=\"panel-grid-cell\" ><div id=\"panel-15563-1-0-0\" class=\"so-panel widget widget_sow-editor panel-first-child\" data-index=\"2\" ><div class=\"so-widget-sow-editor so-widget-sow-editor-base\"><h3 class=\"widget-title\">Configuration<\/h3>\n<div class=\"siteorigin-widget-tinymce textwidget\">\n\t<p>In order to configure the All Okay function from the web interface, firstly we enter full engineer mode and select Configuration, we then select areas and choose the area we wish to use the \u201cAll Okay\u201d functionality on.\u00a0 Find the section marketed \u201cAll Okay\u201d this section has three settings<\/p>\n<p>1 \u2013 On\/Off<\/p>\n<p>2 \u2013 The Time in which the signal must be given, this is default 20s but increase if you feel staff may require additional time.<\/p>\n<p>3 \u2013 The action, this is what the system will do if no signal is given there are three options \u2013 panic, panic silent and duress. The duress and panic silent are both silent alarms however the panic will trigger bells so be aware of this.<\/p>\n<p>&nbsp;<\/p>\n<p>This completes the configuration that a signal is required, next you must configure the device to provide the signal from, within SPC there is a zone type \u201call okay\u201d that can be used to signal, note the area must be the same as area configured above. The indication module in flexible mode can use any of the four buttons to signal that all is okay and the key position on the key switch can also be used.<\/p>\n<\/div>\n<\/div><\/div><div id=\"panel-15563-1-0-1\" class=\"so-panel widget widget_sow-image\" data-index=\"3\" ><div class=\"so-widget-sow-image so-widget-sow-image-default-d6014b76747a-15563\">\n\n<div class=\"sow-image-container\">\n\t\t<img src=\"https:\/\/www.spcsupportinfo.com\/SPCConnectPro\/wp-content\/uploads\/2019\/01\/areaconfiguration.png\" width=\"1392\" height=\"159\" srcset=\"https:\/\/www.spcsupportinfo.com\/SPCConnectPro\/wp-content\/uploads\/2019\/01\/areaconfiguration.png 1392w, https:\/\/www.spcsupportinfo.com\/SPCConnectPro\/wp-content\/uploads\/2019\/01\/areaconfiguration-300x34.png 300w, https:\/\/www.spcsupportinfo.com\/SPCConnectPro\/wp-content\/uploads\/2019\/01\/areaconfiguration-768x88.png 768w, https:\/\/www.spcsupportinfo.com\/SPCConnectPro\/wp-content\/uploads\/2019\/01\/areaconfiguration-1024x117.png 1024w\" sizes=\"(max-width: 1392px) 100vw, 1392px\" alt=\"\" loading=\"lazy\" \t\tclass=\"so-widget-image\"\/>\n\t<\/div>\n\n<\/div><\/div><div id=\"panel-15563-1-0-2\" class=\"so-panel widget widget_sow-editor\" data-index=\"4\" ><div class=\"so-widget-sow-editor so-widget-sow-editor-base\"><h3 class=\"widget-title\">Conslusion<\/h3>\n<div class=\"siteorigin-widget-tinymce textwidget\">\n\t<p>I hope this guide was helpful for you and welcome your <a href=\"https:\/\/www.spcsupportinfo.com\/SPCConnectPro\/?page_id=121\">feedback<\/a> if you have any questions or queries please contact us at Vanderbilt Industries for more information.<\/p>\n<\/div>\n<\/div><\/div><div id=\"panel-15563-1-0-3\" class=\"so-panel widget widget_sow-button panel-last-child\" data-index=\"5\" ><div class=\"so-widget-sow-button so-widget-sow-button-atom-b4f6b6b19f96-15563\"><div class=\"ow-button-base ow-button-align-center\">\n\t<a href=\"https:\/\/www.spcsupportinfo.com\/SPCConnectPro\/?page_id=14334\" class=\"ow-icon-placement-left ow-button-hover\" \t\t>\n\t\t<span>\n\t\t\t\n\t\t\tSPC security solutions \t\t<\/span>\n\t<\/a>\n<\/div>\n<\/div><\/div><\/div><\/div><\/div><\/div>","protected":false},"excerpt":{"rendered":"<p>It is key to protect staff at all times and when a member of your staff has access to secure premises that may contain valuables there is a threat, traditionally the method for signally this was a member of staff to trigger a silent alarm that would be reported to police or to enter a [&hellip;]<\/p>\n","protected":false},"author":20,"featured_media":10698,"parent":2833,"menu_order":5,"comment_status":"closed","ping_status":"closed","template":"page-onecolumn.php","meta":[],"_links":{"self":[{"href":"https:\/\/www.spcsupportinfo.com\/SPCConnectPro\/index.php?rest_route=\/wp\/v2\/pages\/15563"}],"collection":[{"href":"https:\/\/www.spcsupportinfo.com\/SPCConnectPro\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.spcsupportinfo.com\/SPCConnectPro\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.spcsupportinfo.com\/SPCConnectPro\/index.php?rest_route=\/wp\/v2\/users\/20"}],"replies":[{"embeddable":true,"href":"https:\/\/www.spcsupportinfo.com\/SPCConnectPro\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=15563"}],"version-history":[{"count":0,"href":"https:\/\/www.spcsupportinfo.com\/SPCConnectPro\/index.php?rest_route=\/wp\/v2\/pages\/15563\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/www.spcsupportinfo.com\/SPCConnectPro\/index.php?rest_route=\/wp\/v2\/pages\/2833"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.spcsupportinfo.com\/SPCConnectPro\/index.php?rest_route=\/wp\/v2\/media\/10698"}],"wp:attachment":[{"href":"https:\/\/www.spcsupportinfo.com\/SPCConnectPro\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=15563"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}