{"id":15097,"date":"2019-01-08T09:55:16","date_gmt":"2019-01-08T09:55:16","guid":{"rendered":"https:\/\/www.spcsupportinfo.com\/SPCConnectPro\/?page_id=15097"},"modified":"2019-01-08T09:55:16","modified_gmt":"2019-01-08T09:55:16","slug":"cei-abi","status":"publish","type":"page","link":"https:\/\/www.spcsupportinfo.com\/SPCConnectPro\/?page_id=15097","title":{"rendered":"cei-abi Ethernet &#8211; monitoring solutions for Italian banking"},"content":{"rendered":"<div id=\"pl-15097\"  class=\"panel-layout\" ><div id=\"pg-15097-0\"  class=\"panel-grid panel-has-style\" ><div class=\"siteorigin-panels-stretch panel-row-style panel-row-style-for-15097-0\" data-stretch-type=\"full-stretched-padded\" ><div id=\"pgc-15097-0-0\"  class=\"panel-grid-cell\" ><div id=\"panel-15097-0-0-0\" class=\"so-panel widget widget_sow-editor panel-first-child panel-last-child\" data-index=\"0\" ><div class=\"so-widget-sow-editor so-widget-sow-editor-base\"><h3 class=\"widget-title\">Overview <\/h3>\n<div class=\"siteorigin-widget-tinymce textwidget\">\n\t<p><span>Communication card in Ethernet TCP \/ IP protocol in CEI-ABI format (CEI 79-5 \/ 6 - transport\/application level) designed for the BANK world that is equipped with an adequate data reception center.\u00a0Its implementation allows the connection of SPC to any Supervision and Control Center that respects the CEI technical standard.\u00a0<\/span><span>Through this connection, the center, connected on a constant polling data network with the field control units, can send commands and receive the status of the control panel that is updated in real time by the spontaneous sending of event messages or that can be requested in partial or complete form from the center itself.\u00a0\u00a0<\/span><\/p>\n<p>All IP Enabled SPC systems can provide\u00a0CEI-ABI functionality to provide the following operations<\/p>\n<ul>\n<li>Zones\/input status<\/li>\n<li>Alarms<\/li>\n<li>Area status<\/li>\n<li>System control<\/li>\n<li>Door status<\/li>\n<li>Door control<\/li>\n<li>Silence bells<\/li>\n<li>Restore alerts<\/li>\n<li>Bypass Zones<\/li>\n<\/ul>\n<\/div>\n<\/div><\/div><\/div><div id=\"pgc-15097-0-1\"  class=\"panel-grid-cell\" ><div id=\"panel-15097-0-1-0\" class=\"so-panel widget widget_sow-image panel-first-child panel-last-child\" data-index=\"1\" ><div class=\"so-widget-sow-image so-widget-sow-image-default-d6014b76747a-15097\">\n\n<div class=\"sow-image-container\">\n\t\t<img src=\"https:\/\/www.spcsupportinfo.com\/SPCConnectPro\/wp-content\/uploads\/2018\/11\/SPCfamily.jpeg\" width=\"192\" height=\"263\" sizes=\"(max-width: 192px) 100vw, 192px\" title=\"SPCfamily\" alt=\"SPCfamily\" loading=\"lazy\" \t\tclass=\"so-widget-image\"\/>\n\t<\/div>\n\n<\/div><\/div><\/div><\/div><\/div><div id=\"pg-15097-1\"  class=\"panel-grid panel-has-style\" ><div class=\"siteorigin-panels-stretch panel-row-style panel-row-style-for-15097-1\" data-stretch-type=\"full-stretched-padded\" ><div id=\"pgc-15097-1-0\"  class=\"panel-grid-cell\" ><div id=\"panel-15097-1-0-0\" class=\"so-panel widget widget_sow-editor panel-first-child\" data-index=\"2\" ><div class=\"so-widget-sow-editor so-widget-sow-editor-base\"><h3 class=\"widget-title\">How to configure<\/h3>\n<div class=\"siteorigin-widget-tinymce textwidget\">\n\t<p>Via the SPC web page access \"full Engineer\" this will allow you to program the system, select communications -&gt; reporting and\u00a0CEI-ABI, the system is configured to work in two modes<\/p>\n<ul>\n<li>Client mode -\u00a0The panel will connect to the CEI-ABI receiver.<\/li>\n<li>Server mode -\u00a0The panel will listen for connections.<\/li>\n<\/ul>\n<p>You must then configure the server IP address if working in server mode, be sure to check with the receiver configuration manual to configure the physical and logical address of the system.<\/p>\n<p>Once the system is configured the zones, areas and doors status and control should be available in the receiver system.<\/p>\n<p>&nbsp;<\/p>\n<p>Learn more about<\/p>\n<ul>\n<li><a href=\"https:\/\/www.spcsupportinfo.com\/SPCConnectPro\/?page_id=1252\">SPC Communications<\/a><\/li>\n<li class=\"page_item page-item-14394\"><a href=\"https:\/\/www.spcsupportinfo.com\/SPCConnectPro\/?page_id=14394\">SPC Financial solutions intrusion security solutions<\/a><\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<\/div>\n<\/div><\/div><div id=\"panel-15097-1-0-1\" class=\"so-panel widget widget_sow-image panel-last-child\" data-index=\"3\" ><div class=\"so-widget-sow-image so-widget-sow-image-default-17bc2272b535-15097\">\n\n<div class=\"sow-image-container\">\n\t\t<img src=\"https:\/\/www.spcsupportinfo.com\/SPCConnectPro\/wp-content\/uploads\/2019\/01\/abi.png\" width=\"1233\" height=\"359\" srcset=\"https:\/\/www.spcsupportinfo.com\/SPCConnectPro\/wp-content\/uploads\/2019\/01\/abi.png 1233w, https:\/\/www.spcsupportinfo.com\/SPCConnectPro\/wp-content\/uploads\/2019\/01\/abi-300x87.png 300w, https:\/\/www.spcsupportinfo.com\/SPCConnectPro\/wp-content\/uploads\/2019\/01\/abi-768x224.png 768w, https:\/\/www.spcsupportinfo.com\/SPCConnectPro\/wp-content\/uploads\/2019\/01\/abi-1024x298.png 1024w\" sizes=\"(max-width: 1233px) 100vw, 1233px\" alt=\"\" loading=\"lazy\" \t\tclass=\"so-widget-image\"\/>\n\t<\/div>\n\n<\/div><\/div><\/div><\/div><\/div><\/div>","protected":false},"excerpt":{"rendered":"<p>Communication card in Ethernet TCP \/ IP protocol in CEI-ABI format (CEI 79-5 \/ 6 &#8211; transport\/application level) designed for the BANK world that is equipped with an adequate data reception center.\u00a0Its implementation allows the connection of SPC to any Supervision and Control Center that respects the CEI technical standard.\u00a0Through this connection, the center, connected [&hellip;]<\/p>\n","protected":false},"author":20,"featured_media":0,"parent":1252,"menu_order":5,"comment_status":"closed","ping_status":"closed","template":"page-onecolumn.php","meta":[],"_links":{"self":[{"href":"https:\/\/www.spcsupportinfo.com\/SPCConnectPro\/index.php?rest_route=\/wp\/v2\/pages\/15097"}],"collection":[{"href":"https:\/\/www.spcsupportinfo.com\/SPCConnectPro\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.spcsupportinfo.com\/SPCConnectPro\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.spcsupportinfo.com\/SPCConnectPro\/index.php?rest_route=\/wp\/v2\/users\/20"}],"replies":[{"embeddable":true,"href":"https:\/\/www.spcsupportinfo.com\/SPCConnectPro\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=15097"}],"version-history":[{"count":0,"href":"https:\/\/www.spcsupportinfo.com\/SPCConnectPro\/index.php?rest_route=\/wp\/v2\/pages\/15097\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/www.spcsupportinfo.com\/SPCConnectPro\/index.php?rest_route=\/wp\/v2\/pages\/1252"}],"wp:attachment":[{"href":"https:\/\/www.spcsupportinfo.com\/SPCConnectPro\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=15097"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}