{"id":13690,"date":"2018-12-03T10:10:46","date_gmt":"2018-12-03T10:10:46","guid":{"rendered":"https:\/\/www.spcsupportinfo.com\/SPCConnectPro\/?page_id=13690"},"modified":"2019-02-25T15:44:38","modified_gmt":"2019-02-25T15:44:38","slug":"usb-card-reader-for-spc","status":"publish","type":"page","link":"https:\/\/www.spcsupportinfo.com\/SPCConnectPro\/?page_id=13690","title":{"rendered":"USB Card reader for SPC"},"content":{"rendered":"<div id=\"pl-13690\"  class=\"panel-layout\" ><div id=\"pg-13690-0\"  class=\"panel-grid panel-has-style\" ><div class=\"siteorigin-panels-stretch panel-row-style panel-row-style-for-13690-0\" data-stretch-type=\"full-stretched-padded\" ><div id=\"pgc-13690-0-0\"  class=\"panel-grid-cell\" ><div id=\"panel-13690-0-0-0\" class=\"so-panel widget widget_sow-editor panel-first-child panel-last-child\" data-index=\"0\" ><div class=\"so-widget-sow-editor so-widget-sow-editor-base\"><h3 class=\"widget-title\">USB Enrollment reader<\/h3>\n<div class=\"siteorigin-widget-tinymce textwidget\">\n\t<p>Mifare\/USB enrolment reader ford SPC system with AR618x-MF readers.<\/p>\n<p>\u2022 Mifare classic, Ultralight and DESFire SCN<br \/>\n\u2022 Build in USB (2.0) drivers.<br \/>\n\u2022 No external configuration tool needed.<\/p>\n<p>&nbsp;<\/p>\n<p>Design for easy registration RFID cards in the access control software. The card reader interface connects<br \/>\nto a pc via USB (2.0) and the required driver is automatically loaded (Windows, MAC OS &amp; Linux).<br \/>\nWhen presenting a MIFARE\u00ae card or tag to the readID\u2122 MIFARE\u00ae card reader the card data is<br \/>\ntransferred to pc as keyboard data.<br \/>\nThis allows for integration with existing software where card data usually is being typed into the system.<\/p>\n<p>&nbsp;<\/p>\n<\/div>\n<\/div><\/div><\/div><div id=\"pgc-13690-0-1\"  class=\"panel-grid-cell\" ><div id=\"panel-13690-0-1-0\" class=\"so-panel widget widget_sow-image panel-first-child panel-last-child\" data-index=\"1\" ><div class=\"so-widget-sow-image so-widget-sow-image-default-17bc2272b535-13690\">\n\n<div class=\"sow-image-container\">\n\t\t<img src=\"https:\/\/www.spcsupportinfo.com\/SPCConnectPro\/wp-content\/uploads\/2018\/12\/v54504f103a100_er10mf_023_01.jpg\" width=\"5269\" height=\"3249\" srcset=\"https:\/\/www.spcsupportinfo.com\/SPCConnectPro\/wp-content\/uploads\/2018\/12\/v54504f103a100_er10mf_023_01.jpg 5269w, https:\/\/www.spcsupportinfo.com\/SPCConnectPro\/wp-content\/uploads\/2018\/12\/v54504f103a100_er10mf_023_01-300x185.jpg 300w, https:\/\/www.spcsupportinfo.com\/SPCConnectPro\/wp-content\/uploads\/2018\/12\/v54504f103a100_er10mf_023_01-768x474.jpg 768w, https:\/\/www.spcsupportinfo.com\/SPCConnectPro\/wp-content\/uploads\/2018\/12\/v54504f103a100_er10mf_023_01-1024x631.jpg 1024w\" sizes=\"(max-width: 5269px) 100vw, 5269px\" alt=\"\" loading=\"lazy\" \t\tclass=\"so-widget-image\"\/>\n\t<\/div>\n\n<\/div><\/div><\/div><\/div><\/div><div id=\"pg-13690-1\"  class=\"panel-grid panel-has-style\" ><div class=\"siteorigin-panels-stretch panel-row-style panel-row-style-for-13690-1\" data-stretch-type=\"full-stretched-padded\" ><div id=\"pgc-13690-1-0\"  class=\"panel-grid-cell\" ><div id=\"panel-13690-1-0-0\" class=\"so-panel widget widget_sow-editor panel-first-child\" data-index=\"2\" ><div class=\"so-widget-sow-editor so-widget-sow-editor-base\"><h3 class=\"widget-title\">Selecting data format<\/h3>\n<div class=\"siteorigin-widget-tinymce textwidget\">\n\t<p>The firmware in the readID\u2122 MIFARE\u00ae card reader allows for multiple output formats in order to match the card data presentation in the receiving system. The chip serial number of a MIFARE card or tag is stored in binary format but is often displayed in decimal format. To allow easy integration the most commonly used formats have been implemented in the standard firmware. Each format has 2 selectable options, one for enabling \u2018Enter\/CR\u2019 as end of transmission character and<br \/>\none for enabling format specific options like padding (#xxx\u2026xxx#) or 56 Bit support.<\/p>\n<\/div>\n<\/div><\/div><div id=\"panel-13690-1-0-1\" class=\"so-panel widget widget_sow-editor\" data-index=\"3\" ><div class=\"so-widget-sow-editor so-widget-sow-editor-base\"><h3 class=\"widget-title\">Installation and configuration<\/h3>\n<div class=\"siteorigin-widget-tinymce textwidget\">\n\t<ol>\n<li>Follow these steps to install and use the reader:<br \/>\nConnect the reader to a USB port of the PC. Initially the LED is red while the driver is downloaded to the<br \/>\nPC approximately 1 minute. The LED gets green and finally blue when the reader is ready to read cards.<\/li>\n<li>\u00a0Start a text editor like Notepad or Word.<\/li>\n<li>Locate the small hole in the reader, usually at the same side as the cable. Use a stick to reach the reset<br \/>\nbutton.<\/li>\n<li>Press and hold. The LED becomes green and buzzes.<\/li>\n<li>The Quick Config text is sent from the reader to the editor as long as the stick is held on the reset but<br \/>\nton. Currently, there are five different formats available:<br \/>\nl ALIRO + AR10\/AR40<br \/>\nl ALIRO + AR6181\/AR6182<br \/>\nl SPC + AR6181\/AR6182<br \/>\nl SPC + WIEGAND 32 BIT RDR<br \/>\nl OMNIS + AR10\/AR40<\/li>\n<li>\u00a0Release the stick as soon as you see the correct format. A double tone is heard when the format is set.<br \/>\nKindly note that if you miss the correct format, repeat from step 4. And the selected settings will be saved<br \/>\nand kept for future use even if the ER10-MF is disconnected from the PC.<\/li>\n<\/ol>\n<\/div>\n<\/div><\/div><div id=\"panel-13690-1-0-2\" class=\"so-panel widget widget_sow-editor panel-last-child\" data-index=\"4\" ><div class=\"so-widget-sow-editor so-widget-sow-editor-base\"><h3 class=\"widget-title\">Using the reader<\/h3>\n<div class=\"siteorigin-widget-tinymce textwidget\">\n\t<p>When the configuration is done the reader is ready for use together with the intended system.<br \/>\n1. Start the application.<br \/>\n2. Locate the card input menus or dialogues.<br \/>\n3. Place the cursor in the card number field.<br \/>\n4. Present the card for the reader.<br \/>\n5. The card number, in the selected format, is visible in the field and ready for use.<br \/>\n6. Repeat for each necessary card.<\/p>\n<\/div>\n<\/div><\/div><\/div><\/div><\/div><div id=\"pg-13690-2\"  class=\"panel-grid panel-has-style\" ><div class=\"siteorigin-panels-stretch panel-row-style panel-row-style-for-13690-2\" data-stretch-type=\"full-stretched-padded\" ><div id=\"pgc-13690-2-0\"  class=\"panel-grid-cell\" ><div id=\"panel-13690-2-0-0\" class=\"so-panel widget widget_sow-editor panel-first-child panel-last-child\" data-index=\"5\" ><div class=\"so-widget-sow-editor so-widget-sow-editor-base\"><h3 class=\"widget-title\">How to Order<\/h3>\n<div class=\"siteorigin-widget-tinymce textwidget\">\n\t<p>ER10-MF - ER10-MF Enrollment reader, Mifare, USB<\/p>\n<p>Order number<br \/>\nV54504-F103-A100<\/p>\n<\/div>\n<\/div><\/div><\/div><\/div><\/div><\/div>","protected":false},"excerpt":{"rendered":"<p>Mifare\/USB enrolment reader ford SPC system with AR618x-MF readers. \u2022 Mifare classic, Ultralight and DESFire SCN \u2022 Build in USB (2.0) drivers. \u2022 No external configuration tool needed. &nbsp; Design for easy registration RFID cards in the access control software. The card reader interface connects to a pc via USB (2.0) and the required driver [&hellip;]<\/p>\n","protected":false},"author":20,"featured_media":13693,"parent":1530,"menu_order":45,"comment_status":"closed","ping_status":"closed","template":"page-onecolumn.php","meta":[],"_links":{"self":[{"href":"https:\/\/www.spcsupportinfo.com\/SPCConnectPro\/index.php?rest_route=\/wp\/v2\/pages\/13690"}],"collection":[{"href":"https:\/\/www.spcsupportinfo.com\/SPCConnectPro\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.spcsupportinfo.com\/SPCConnectPro\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.spcsupportinfo.com\/SPCConnectPro\/index.php?rest_route=\/wp\/v2\/users\/20"}],"replies":[{"embeddable":true,"href":"https:\/\/www.spcsupportinfo.com\/SPCConnectPro\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=13690"}],"version-history":[{"count":0,"href":"https:\/\/www.spcsupportinfo.com\/SPCConnectPro\/index.php?rest_route=\/wp\/v2\/pages\/13690\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/www.spcsupportinfo.com\/SPCConnectPro\/index.php?rest_route=\/wp\/v2\/pages\/1530"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.spcsupportinfo.com\/SPCConnectPro\/index.php?rest_route=\/wp\/v2\/media\/13693"}],"wp:attachment":[{"href":"https:\/\/www.spcsupportinfo.com\/SPCConnectPro\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=13690"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}